CHJBQ - TECHNESCAN DTPA
- MSDS: CHJBQ
- Manufacturer: MALLINCKRODT INC
- Product Name: TECHNESCAN DTPA
- National Stock Number: 6550-00N040066
Product Identification
Product ID:TECHNESCAN DTPA
MSDS Date:01/01/1997
FSC:6550
NIIN:00N040066
MSDS Number: CHJBQ
Responsible Party
MARYLAND HEIGHTS, MO 63043
US
Emergency Phone: 314-770-7860;800-424-9300(CHEMTREC)
Info Phone: 314-770-7800
Cage: DO440
Contractor
Telephone: 314-982-5000
Cage: DO440
Ingredients
STANNOUS CHLORIDE
CAS: 7772-99-8
RTECS: XP8700000
Fraction By Weight: 1.3%
OSHA PEL 2 MG/M3 SN
ACGIH TLV: 2 MG/M3 SN
PENTETATE CALCIUM TRISODIUM
CAS: 12111-24-9
RTECS: MB8210000
Fraction By Weight: 98.7%
OSHA PEL 2 MG/M3 SN
ACGIH TLV: 2 MG/M3 SN
RECONSTITUTED KIT CONTAINING INGREDIENT 4
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
TECHNETIUM TC 99M PERTECHNETATE; (TECHNETIUM-99M)
CAS: 23288-60-0
OSHA PEL N/K
ACGIH TLV: N/K
OTHER APPLIC REGS. IF MED WASTE IS
RTECS: 9999999ZZ
HANDLED AS BIOHAZARD & DISPOSED OF ACCORDINGLY. IF
RTECS: 9999999ZZ
CONSIDERED NON-HAZARDOUS. CONSULT LOCAL, STATE &
RTECS: 9999999ZZ
STORED AT 15C TO 30C & DISCARDED AFTER
RTECS: 9999999ZZ
BE KEPT TO MINIMUM & APPROP SHIELDING SHOULD BE
RTECS: 9999999ZZ
SHOULD BE USED. STORAGE & DISPOSAL OF PROD SHOULD BE
RTECS: 9999999ZZ
REGS OF GOVERNMENT AGENCY AUTHORIZED TO LICENSE THE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HAZ INGREDS FOUND IN TECHNESCAN DTPA
ARE SKIN & EYE IRRITANTS, BUT DUE TO SMALL QTYS PRESENT IN CNTNRS,
NO ADVERSE HEALTH EFFECTS ARE EXPECTED TO OCCUR FROM EXPOS. INHAL:
NOT EXPECTED TO BE A HEALTH H AZ. INGEST: NOT EXPECTED TO BE A
HEALTHHAZ. SKIN/EYE CNTCT: NOT EXPECTED TO BE A HEALTH HAZ.
CHRONIC: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: NOT EXPECTED TO BE A CHRONIC HEALTH
HAZ. TOXICOLOGICAL INFO: FOR DETAILED TOXICOLOGICAL INFO ON
SPECIFIC COMPONENTS, WRITE TO MFR-ATTN REGULATORY COMPLIANCE
DEPARTMENT. WHEN THIS KIT IS RECO NSTITUTED W/RADIOACTIVE MATERIAL,
THIS PRODUCT CONTAINS A SUBSTANCE KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.
First Aid
First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) . SKIN: WASH
EXPOSED AREA WITH SOAP AND WATER. SEEK MEDICAL ATTENTION IF IR
RITATION DEVELOPS. EYES: WASH THOROUGHLY WITH RUNNING WATER FOR AT
LEAST 15 MINUTES. GET MEDICAL ATTENTION IF IRRITATION DEVELOPS.
Fire Fighting
Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE OR EXPLOSION
HAZARD.
Accidental Release
Spill Release Procedures:COLLECT NON-RADIOACTIVE SPILLS & DISPOSE OF
MATL AS NON-HAZ WASTE. FOR TECHNESCAN DTPA RECONSTITUTED W/SODIUM
PERTECHNETATE TC-99M: IF ANY LOSS OR RELEASE OF RADIOACTIVE
CONTENTS OCCURS, NOTIFY YOUR R ADIATION SAFETY DEPARTMENT &
MALLINCKRODT (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:THE DRUG SHOULD BE STORED AT 15C TO
30C PRIOR TO RECONSTITUTION W/SODIUM PERTECHNETATE TC-99M. AFTER
RECONSTITUTION, SHIELDED VIAL SHOULD BE (ING 8)
Other Precautions:READ PACKAGE INSERT PRIOR TO USE! PROMPTLY REMOVE ANY
CONTAMINATION FROM SKIN, EYES OR CLOTHING. AVOID ALL UNNECESSARY
EXPOSURE TO THE CHEMICAL SUBSTANCE.
Exposure Controls
Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF
CONCERN .
Ventilation:NOT EXPECTED TO REQUIRE ANY SPECIAL VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
WEAR CLEAN BODY-COVERING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
BP: 212F,100C RECONSTITUTED. MP: 32F,0C RECONSTITUTED. SPILL PROC: AT
314-770-7800. ALL CLEANUP OPERATIONS SHOULD BE PERFORMED ACCORDING
TO STANDARD OPERATING PROCEDURES (SOPS) ESTABLISHED FOR YOUR FA
CILITY & BY NRC OR OTHER APPLICABLE LOCAL, STATE & FEDERAL
REGULATIONS.
Chemical Properties
Boiling Pt:B.P. Text:SUPDAT
Melt/Freeze Pt:M.P/F.P Text:SUPDAT
Solubility in Water:SOLUBLE
Appearance and Odor:SMALL, DRY, WHITE CRYSTALS CLINGING TO INSIDE OF 10
ML GLASS VIAL. ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION,
SUBSTANCE MAY EMIT OXIDES OF CARBON AND CORROSIVE FUMES OF
HYDROCHLORIC ACID.
Disposal
Waste Disposal Methods:TECHNESCAN DPTA RECONSTITUTED W/SODIUM
PERTECHNETATE TC-99M IS RADIOACTIVE WASTE UNTIL ACTIVITY HAS BEEN
DECAYED TO NONDETECTABLE LEVELS. RADIOACTIVE WASTE MUST BE HANDLED
I/A/W PROCEDURES ESTABLISHED BY YOUR RADIATION SAFETY OFFICER, NRC
& (ING 5)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.